Donaldson Torit CPV-1 Specifications Page 19

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 18
Torit PowerCore, CPV-1 to CPV-12
16
Side-Mount Power Pack
Electrical service or maintenance
work must be performed by
a qualified electrician and comply with all
applicable national and local codes.
Turn power off and lock out electrical
power sources before performing service or
maintenance work.
Do not install in classified hazardous
atmospheres without an enclosure rated for
the application.
Mounting a power pack on the
side of a collector requires a
power pack adapter to support the weight of
the power pack.
Poorly installed power packs may separate
from the collector resulting in personal injury
and damage to equipment or property.
1. Disconnect power supply.
2. Apply 1/4-in diameter rope-type sealant to the
outside surface of the power pack adapter between
the fan mount bolt holes and the round fan inlet hole.
3. Install the fan housing to the power pack adapter
using 3/8 x 1 1/4-in bolts, flat washers, and hex nuts.
Install bolts with the bolt head in
the fan housing and the threaded
end in the power pack adapter.
4. Reinstall the motor, bracket, and fan wheel assembly.
Align motor mount bracket to the mark on the
housing on 30 Hp/60 Hz and 20-30 Hp/50 Hz units.
Other motor sizes do not require alignment, but
consider the electrical connection location.
5. Connect power supply to the motor. Turn the fan
motor ON then OFF to check motor rotation by
referencing the rotation arrow on the blower.
To change rotation on three
phase units, turn power supply
OFF and switch any two leads on the output
side of the fan motor starter.
NOTICE
NOTICE
Do not look into fan outlet to
determine rotation. View the fan
rotation from the back of the motor.
Check that the exhaust plenum is free of tools
or debris before checking blower/fan rotation.
Stand clear of exhaust to avoid personal injury.
To reverse rotation, three-phase power supply: Turn
electrical power OFF at source and switch any two
leads on the output-side of the fan motor starter.
Do not interchange a power lead
with the ground wire. Severe
personal injury or equipment damage may
result.
power pack adapter
CPV-2, -3, or -4 Side Mount Power Pack
power pack adapter
CPV-6, -8, or -12 Side Mount Power Pack