Magnehelic Gauge, Detail A
Caution!
Electrical installation must be
performed by a qualified electrician
and comply with all applicable
national and local codes.
Turn power OFF during installation
or maintenance.
Do not install in classified hazardous
atmospheres without an enclosure
rated for the application.
6. Mount the gauge and bracket assembly to the
supporting structure using two, self-drilling
screws.
7. Thirty-five feet of plastic tubing is supplied and
must be cut in two sections. Connect one
section of tubing from the gauge’s high-pressure
port to the pressure fitting located in the dirty-
air plenum. Connect remaining tubing from the
gauge’s low-pressure port to the fitting in the
clean-air plenum. Additional tubing can be
ordered from your representative.
8. Carefully remove the cloth protecting the
filters. Close access doors and tighten securely
by hand.
9. Zero and maintain the gauge as directed in the
manufacturer’s Operating and Maintenance
Instructions provided.
Photohelic Gauge
The Photohelic combines the functions of a
differential pressure gauge and a pressure-based
switch. The gauge function measures the pressure
difference between the clean- and dirty-air
chambers and provides a visual display of filter
condition. The high-pressure tap is located in the
dirty-air plenum and a low-pressure tap is located
in the clean-air plenum. The pressure-based switch
function provides high-pressure ON and low-
pressure OFF control of the filter cleaning system.
1. Choose a convenient, accessible location near
the unit that provides the best visual advantage.
2. Mount the gauge to the remote panel or door
using the mounting ring, retaining ring, and
four #6-32 x 1 1/4-in screws. Do not tighten
screws. Connect two, 1/8-in NPT x 1/4-in OD
male adapters to the gauge’s high- and low-
pressure ports. Align the adapters to the 2.375-in
hole in the right-hand side of the mounting
bracket. Tighten screws.
3. On the back of the gauge, remove four #6-32 x
5/16-in screws and plastic enclosure. Set aside.
Add two jumper wires supplied by customer.
Remove the jumper from the pressure switch
located on the timer board, if equipped. Using
the 3/4-in conduit opening, wire the gauge as
shown. Reassemble and fasten the enclosure
securely.
6.00
16.00
6.00
.406"
dia (2x)