Preliminary Start-Up Check
1. Check all electrical connections for tightness and
contact.
2. Check for and remove all loose items in or near
the inlet and outlet of the unit.
3. Check that all remote controls are wired into the
control system and all service switches are in the
OFF position.
4. Check that all optional accessories are installed
properly and secured.
5. Check that hopper discharge is open and the
storage container is sealed, if equipped.
6. Turn power ON at source.
7. Turn the compressed-air supply ON. Adjust
pressure regulator for 90-psi.
8. Turn the fan motor ON then OFF to check
for proper rotation by referencing the rotation
arrow located on the motor’s mounting plate.
Do not look into fan outlet to
determine rotation. View the
fan rotation through the back of the motor.
Check that the exhaust plenum is free of
tools or debris before checking blower/fan
rotation.
Stand clear of exhaust to avoid personal
injury.
To reverse rotation, single-phase power supply:
Follow manufacturer’s instructions on the
motor’s nameplate.
To reverse rotation, three-phase power supply:
Turn electrical power OFF at source and switch
any two leads on the output-side of the fan-
motor starter.
9. Adjust the blower/fan for proper airflow by
adjusting the volume control damper on the
blower/fan discharge, if equipped.
Excess airflow can shorten
filter life, cause electrical
system failure, and blower motor failure.
NOTICE
Start-Up
1. Turn compressed-air supply ON. Adjust
regulator to 90-psi.
2. Turn blower fan motor ON.
3. Adjust airflow using the airflow control damper,
if equipped.
Service Information
Turn power off / lock out
electrical power sources before
performing service or maintenance work.
Turn compressed air supply OFF and
bleed lines before performing service or
maintenance work.
Operational Checklist
1. Monitor overall performance of the collector.
2. Monitor exhaust.
3. Monitor pressure drop across filters.
4. Monitor dust disposal.
Filter Element Removal
Place filter part-number
label (supplied with each
replacement filter) over the filter part
number listed on the unit’s rating plate.
1. After compressed air supply and electrical power
have been turned off, open the roof access door
of the TBV unit to its fully open position. Make
sure that the small notch on the roof support
slide bar drops down and locks into position,
securing the roof access panel.
Failure to open the door
properly could result in
personal injury. Ensure the door is in the
correct open position.
2. Reach inside the clean air plenum of the unit
and disconnect the blowpipes by pulling back
the levers of the quick-disconnect pipe couplers.
Stow the blowpipes in the upright position by
inserting them into the slots provided at the rear
of the unit.
3. Reach down inside the clean air plenum of the
unit and halfway unscrew all the black hold-